| T60E Tube Axials | |
| Dimension Drawing |

| Free-Running Model* |
Air Flow (CFM) |
Max. Static Pressure (inwg) |
Nominal Voltage (V) |
Voltage Range (V) |
Current (A) |
Input Power (W) |
Sound Level | Bearing | Operating Temp. Min/Max (°C) |
|
| Sound Pressure (dBA) |
NPEL (IPC- 9591) |
|||||||||
| T60E12BUA5-51 | 72 | 2.20 | 12 | 7.0-13.8 | 2.30 | 27.6 | 59.8 | 7.7 Bels | Ball | -10/+70 |
| T60E12BHA5-51 | 58 | 1.53 | 12 | 7.0-13.8 | 1.20 | 14.4 | 57.0 | | Ball | -10/+70 |
| T60E12BLA5-51 | 44 | 0.84 | 12 | 7.0-13.8 | 0.55 | 6.6 | 48.0 | | Ball | -10/+70 |
* Monitor and control options, designated by the last characters of model names, are described here. |
||||||||||



| Free-Running T60E12BUA5 | ||||
| Operating Voltage (V) |
Fraction of Max. Air Flow |
Fan Speed (rpm) |
Static Pressure (inwg) |
NPEL (Bels) |
| 13.8 | 100% | 14260 | 0 | 8.2 |
| 80% | 14250 | 0.65 | 8.2 | |
| 20% | 14690 | 1.83 | 8.1 | |
| 12.0 | 100% | 13000 | 0 | 7.7 |
| 80% | 13090 | 0.56 | 7.8 | |
| 20% | 13680 | 1.60 | 8.0 | |
| 7.0 | 100% | 7450 | 0 | 6.2 |
| 80% | 7475 | 0.19 | 6.4 | |
| 20% | 7640 | 0.55 | 6.8 | |
| Sound levels in the table are mean values, measured as the fans - without guards or other accessories - expel air from a test plenum on which they are mounted, using test methods and conventions prescribed by IPC-9591. | ||||
T60E12BL T60E12BLA5 T60E12BLA5-51 T60E12BLA5-52 T60E12BLA5-53 T60E12BLA5-54 T60E12BLA5-55 T60E12BLA5-56 T60E12BLA5-57 T60E12BLA5-58 T60E12BLA5-59 T60E12BLA5-60 T60E12BLA5-61 T60E12BLA5-62 T60E12BLA5-63 T60E12BLA5-64
T60E12BH T60E12BHA5 T60E12BHA5-51 T60E12BHA5-52 T60E12BHA5-53 T60E12BHA5-54 T60E12BHA5-55 T60E12BHA5-56 T60E12BHA5-57 T60E12BHA5-58 T60E12BHA5-59 T60E12BHA5-60 T60E12BHA5-61 T60E12BHA5-62 T60E12BHA5-63 T60E12BHA5-64
T60E12BU T60E12BUA5 T60E12BUA5-51 T60E12BUA5-52 T60E12BUA5-53 T60E12BUA5-54 T60E12BUA5-55 T60E12BUA5-56 T60E12BUA5-57 T60E12BUA5-58 T60E12BUA5-59 T60E12BUA5-60 T60E12BUA5-61 T60E12BUA5-62 T60E12BUA5-63 T60E12BUA5-64